Overview:
DSY-DWDF10-12/24 adopts prefabricated, touchable, live silicone rubber cable heads, which are fully sealed, fully insulated, and maintenance-free, ensuring reliable personal safety. The structure is compact, with a small and aesthetically pleasing appearance. The double-layer stainless steel cabinet has a service life of more than 20 years. Under the premise of not affecting the operation of the main network, it allows for regional power outages for maintenance, reducing the range of power outages. It can be equipped with one or more ring main units. The wiring options are flexible and diverse, with up to eight branch circuits. Optional components include lightning arresters, short-circuit fault indicators, current-limiting fuses, etc., This switchgear to meet various user requirements.
Features:
- Adopts prefabricated, touchable, live silicone rubber cable heads, fully sealed, fully insulated, maintenance-free, ensuring reliable personal safety;
- Compact structure with a small and aesthetically pleasing appearance, featuring a double-layer stainless steel cabinet with a service life of over 20 years;
- Allows for regional power outages for maintenance without affecting the operation of the main network, reducing the outage range;
- Can be equipped with one or more SF6 load switches. The wiring options are flexible and diverse, with up to 8 branch circuits;
- Optional components include lightning arresters, short-circuit fault indicators, and current-limiting fuses, to meet various user requirements.
Electrical technical parameters:
Project |
Parameter |
Parameter |
Rated current |
12kV |
24kV |
Rated volatge |
630A |
630A |
Power frequency withstand voltage (phase to ground) |
42kV/min |
79kV/min |
Lightning impulse voltage |
75kV |
95kV |
Rated breaking current |
630A |
630A |
Rated short-circuit breaking current (peak value) |
50kA |
50kA |
Rated short-time withstand current |
25kA/4S |
25kA/4S |
Rated peak withstand current |
50kA |
50kA |
Rated breaking capacitance current |
45A |
45A |
Rated breaking inductance current |
16A |
16A |
Full load breaking times |
>100 |
>100 |
Number of mechanical operations of opening and closing |
2000 |
2000 |
Typical wiring scheme:
Design No. |
A Wiring Diagram |
Design No. |
A Wiring Diagram |
01 |
|
02 |
|
03 |
|
04 |
|
05 |
|
06 |
|
07 |
|
08 |
|
09 |
|
10 |
|
11 |
|
12 |
|
Keywords
DSY-DWDF10-12/24 Intelligent Metal Outdoor Switchgear Station
隐藏域元素占位
Subcategory
Contact Us
- 产品描述
-
- Commodity name: DSY-DWDF10-12/24 Intelligent Metal Outdoor Switchgear Station
DSY-DWDF10-12/24 adopts prefabricated, touchable, live silicone rubber cable heads, which are fully sealed
Overview:
DSY-DWDF10-12/24 adopts prefabricated, touchable, live silicone rubber cable heads, which are fully sealed, fully insulated, and maintenance-free, ensuring reliable personal safety. The structure is compact, with a small and aesthetically pleasing appearance. The double-layer stainless steel cabinet has a service life of more than 20 years. Under the premise of not affecting the operation of the main network, it allows for regional power outages for maintenance, reducing the range of power outages. It can be equipped with one or more ring main units. The wiring options are flexible and diverse, with up to eight branch circuits. Optional components include lightning arresters, short-circuit fault indicators, current-limiting fuses, etc., This switchgear to meet various user requirements.
Features:
- Adopts prefabricated, touchable, live silicone rubber cable heads, fully sealed, fully insulated, maintenance-free, ensuring reliable personal safety;
- Compact structure with a small and aesthetically pleasing appearance, featuring a double-layer stainless steel cabinet with a service life of over 20 years;
- Allows for regional power outages for maintenance without affecting the operation of the main network, reducing the outage range;
- Can be equipped with one or more SF6 load switches. The wiring options are flexible and diverse, with up to 8 branch circuits;
- Optional components include lightning arresters, short-circuit fault indicators, and current-limiting fuses, to meet various user requirements.
Electrical technical parameters:
Project
Parameter
Parameter
Rated current
12kV
24kV
Rated volatge
630A
630A
Power frequency withstand voltage (phase to ground)
42kV/min
79kV/min
Lightning impulse voltage
75kV
95kV
Rated breaking current
630A
630A
Rated short-circuit breaking current (peak value)
50kA
50kA
Rated short-time withstand current
25kA/4S
25kA/4S
Rated peak withstand current
50kA
50kA
Rated breaking capacitance current
45A
45A
Rated breaking inductance current
16A
16A
Full load breaking times
>100
>100
Number of mechanical operations of opening and closing
2000
2000
Typical wiring scheme:
Design No.
A Wiring Diagram
Design No.
A Wiring Diagram
01
02
03
04
05
06
07
08
09
10
11
12
We Provide More Services That Make Sure Your Projects Safe, Reliable And Efficient