YBW-40.5/0.69-4000 Energy box-type Prefabricated Substation
+
  • YBW-40.5/0.69-4000 Energy box-type Prefabricated Substation

Product Overview:

  • The box transformer is divided into three parts: high-voltage room, low-voltage room and transformer, arranged in the shape of a “目”. Except for the transformer heat sink and the body exposed outside the box, all other live compartments are sealed.
  • In independent compartments. Each room is separated into independent compartments by partitions, and a manhole is provided inside the body for easy installation and maintenance.
  • The inner and outer surfaces of the box are flat, without rust, coating shedding and bump damage. The coating layer is firm and uniform, without obvious contrast reflection.
  • The box base and all exposed metal parts are treated with anti-corrosion and anti-rust treatment, and a durable protective layer is sprayed.
  • The box top cover is equipped with a rainproof sealing cover and rainproof eaves, and the double-layer box top cover can prevent heat radiation.
  • The design size of the box transformer door matches the size of the installed equipment. The box transformer door adopts an internal hinge, and all doors on the box open outwards with an opening angle greater than 90°.
  • The box is made of stainless steel, and the paint is imported car paint. All are baked paint, which is smoke-proof, heat-proof, mildew-proof, and has strong outdoor weather resistance.
  • The area where the photovoltaic power station is located has low temperature, large temperature difference, high humidity, and much wind and sand. The box transformer has a reasonable protective structure, dustproof structure and low temperature resistance, which can meet the requirements of normal and safe operation under harsh environmental conditions.

 

Working Environment:

  • Altitude generally does not exceed 3000m;
  • Ambient temperature range: -40℃~+85℃;
  • Outdoor wind speed does not exceed 35m/s;
  • Shockproof: horizontal acceleration 0.3m/s; vertical acceleration not more than 0.15m/s;
  • Pollution-proof level: Level I;
  • Installation location: Outdoor;

 

Technical Parameters

  • Electrical uranium edge
  • Rated voltage of high voltage side: 6kV, 12kV, 24kV, 35kV, 36.75kV, 38.5kV
  • Low voltage side rated voltage: 0.27kV, 0.3kV, 0.315kV, 0.4kV
  • Rated frequency: 50Hz
  • Number of phases: three phases
  • Protection level: IP68 for fuel tank, IP54 for high and low pressure chamber, IP3X after high pressure chamber door is opened

 

Conventional Transformer Technical Parameters:

Name Parameter
Transformer capacity kVA 500~1600
High voltage kV 6、12、24、35、36.75、38.5
Tap range 士2×2.5
loin group label 0.315、0.27、0.3、0.4
No load loss KW yd11, d111
No load loss KW According to customer’s requirements
Load loss KW According to customer’s requirements

 

High Voltage Vacuum Isolated Load Switch, Fuse Combination Eectrical Equipment:

Name Parameters
Model number FZRN25-12D (Manual and electric operation) FZRN21C-40.5D (Manual and electric operation
Voltage level (kV) 12 40.5
Power frequency withstand voltage (kV) 45 95
Lightningimpulse voltage (kV) 75 185
Rated current(A) The fuse shall prevail The fuse shall prevail
Rated short-time breaking current (kA) 20/31.5 20/31.5
Mechanical life 10000 Times 10000 Times

Keywords

YBW-40.5/0.69-4000 Energy box-type Prefabricated Substation


The box transformer is divided into three parts: high-voltage room, low-voltage room and transformer, arranged in the shape of a “目”. Except for the transformer heat sink and the body exposed outside the box, all other live compartments are sealed.

隐藏域元素占位

  • 产品描述
    • Commodity name: YBW-40.5/0.69-4000 Energy box-type Prefabricated Substation

    The box transformer is divided into three parts: high-voltage room, low-voltage room and transformer, arranged in the shape of a “目”. Except for the transformer heat sink and the body exposed outside the box, all other live compartments are sealed.

    Product Overview:

    • The box transformer is divided into three parts: high-voltage room, low-voltage room and transformer, arranged in the shape of a “目”. Except for the transformer heat sink and the body exposed outside the box, all other live compartments are sealed.
    • In independent compartments. Each room is separated into independent compartments by partitions, and a manhole is provided inside the body for easy installation and maintenance.
    • The inner and outer surfaces of the box are flat, without rust, coating shedding and bump damage. The coating layer is firm and uniform, without obvious contrast reflection.
    • The box base and all exposed metal parts are treated with anti-corrosion and anti-rust treatment, and a durable protective layer is sprayed.
    • The box top cover is equipped with a rainproof sealing cover and rainproof eaves, and the double-layer box top cover can prevent heat radiation.
    • The design size of the box transformer door matches the size of the installed equipment. The box transformer door adopts an internal hinge, and all doors on the box open outwards with an opening angle greater than 90°.
    • The box is made of stainless steel, and the paint is imported car paint. All are baked paint, which is smoke-proof, heat-proof, mildew-proof, and has strong outdoor weather resistance.
    • The area where the photovoltaic power station is located has low temperature, large temperature difference, high humidity, and much wind and sand. The box transformer has a reasonable protective structure, dustproof structure and low temperature resistance, which can meet the requirements of normal and safe operation under harsh environmental conditions.

     

    Working Environment:

    • Altitude generally does not exceed 3000m;
    • Ambient temperature range: -40℃~+85℃;
    • Outdoor wind speed does not exceed 35m/s;
    • Shockproof: horizontal acceleration 0.3m/s; vertical acceleration not more than 0.15m/s;
    • Pollution-proof level: Level I;
    • Installation location: Outdoor;

     

    Technical Parameters

    • Electrical uranium edge
    • Rated voltage of high voltage side: 6kV, 12kV, 24kV, 35kV, 36.75kV, 38.5kV
    • Low voltage side rated voltage: 0.27kV, 0.3kV, 0.315kV, 0.4kV
    • Rated frequency: 50Hz
    • Number of phases: three phases
    • Protection level: IP68 for fuel tank, IP54 for high and low pressure chamber, IP3X after high pressure chamber door is opened

     

    Conventional Transformer Technical Parameters:

    Name Parameter
    Transformer capacity kVA 500~1600
    High voltage kV 6、12、24、35、36.75、38.5
    Tap range 士2×2.5
    loin group label 0.315、0.27、0.3、0.4
    No load loss KW yd11, d111
    No load loss KW According to customer’s requirements
    Load loss KW According to customer’s requirements

     

    High Voltage Vacuum Isolated Load Switch, Fuse Combination Eectrical Equipment:

    Name Parameters
    Model number FZRN25-12D (Manual and electric operation) FZRN21C-40.5D (Manual and electric operation
    Voltage level (kV) 12 40.5
    Power frequency withstand voltage (kV) 45 95
    Lightningimpulse voltage (kV) 75 185
    Rated current(A) The fuse shall prevail The fuse shall prevail
    Rated short-time breaking current (kA) 20/31.5 20/31.5
    Mechanical life 10000 Times 10000 Times

Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit