GCK low-voltage withdrawable switchgear
+
  • GCK low-voltage withdrawable switchgear

Oveview:

GCK low-voltage withdrawable switchgear consists of two parts: power distribution center (PC) switchgear and motor control center (MCC). It is suitable for power users such as power plants, substations, industrial and mining enterprises as a power distribution system with AC 50Hz, maximum working voltage up to 660V, and maximum working current up to 3150A, and is used for power distribution, motor control, lighting and other distribution equipment.

Basic parameters:

Project Parameter
Rated working frequency (Hz) 50Hz
Rated working voltage (V) 380V, 660V
Rated insulation voltage (V) 660V
Rated working current (A) Horizontal busbar, vertical busbar 630A-3150A、600A
Rated short-time without standing current Horizontal busbar, vertical busbar 80kA (rms)/1 second 50 kA (rms)/1 second
Rated peak withstand current Horizontal busbar, vertical busbar 176kA/0.1 s, 110kA/0.1 s
Main circuit connector (A) 200A, 400A
Auxiliary circuit connector (A) 10A
Power frequency withstand voltage for 1 minute (V) 2500V
Protection level IP40
Operation method On-site, remote, automatic

GCK low-voltage withdrawable switchgear


GCK low-voltage withdrawable switchgear consists of two parts: power distribution center (PC) switchgear and motor control center (MCC).

隐藏域元素占位

  • 产品描述
    • Commodity name: GCK low-voltage withdrawable switchgear

    GCK low-voltage withdrawable switchgear consists of two parts: power distribution center (PC) switchgear and motor control center (MCC).

    Oveview:

    GCK low-voltage withdrawable switchgear consists of two parts: power distribution center (PC) switchgear and motor control center (MCC). It is suitable for power users such as power plants, substations, industrial and mining enterprises as a power distribution system with AC 50Hz, maximum working voltage up to 660V, and maximum working current up to 3150A, and is used for power distribution, motor control, lighting and other distribution equipment.

    Basic parameters:

    Project Parameter
    Rated working frequency (Hz) 50Hz
    Rated working voltage (V) 380V, 660V
    Rated insulation voltage (V) 660V
    Rated working current (A) Horizontal busbar, vertical busbar 630A-3150A、600A
    Rated short-time without standing current Horizontal busbar, vertical busbar 80kA (rms)/1 second 50 kA (rms)/1 second
    Rated peak withstand current Horizontal busbar, vertical busbar 176kA/0.1 s, 110kA/0.1 s
    Main circuit connector (A) 200A, 400A
    Auxiliary circuit connector (A) 10A
    Power frequency withstand voltage for 1 minute (V) 2500V
    Protection level IP40
    Operation method On-site, remote, automatic

Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit