DSY-CV-12/T630-20 Environmentally friendly gas insulated ring main switchgear
+
  • DSY-CV-12/T630-20 Environmentally friendly gas insulated ring main switchgear

Overview:

Since the 1950s, the development of medium-voltage switchgear has gone through the stages of open type, box type, metal enclosed type, etc. There is no problem in meeting the functional use requirements of the equipment, and the products have long been serialized and fully covered. Small size, maintenance-free, highly modular, safe and reliable environmentally friendly gas-insulated ring network switchgear has developed rapidly. It can realize remote monitoring, control and management of the power system distribution network, realize the needs of power grid optimization, power safety, power management, energy saving and consumption reduction: the system can also be widely used in intelligent power distribution fields such as transportation, factories, hospitals, schools, buildings, residential areas and commercial office buildings.

DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear fully introduces advanced production equipment and manufacturing technology to realize localized production, greatly reduce manufacturing costs, shorten delivery cycles, and is well received by users after its launch.

1. Secondary control box
2. Microcomputer integrated protection device
3. Live indicator
The live indicator shows whether the bushing is live. The three sockets below the indicator can be used for secondary phase checking.
4. Energy storage operation hole
Use the operating handle to rotate the energy storage mechanism shaft. Make the main switch operating mechanism store energy
5. Energy storage operation hole padlock device
The padlock plate linked to the padlock device blocks the energy storage operation hole. Only by pulling the padlock device can the operating handle be inserted into the energy storage operation hole. When not in operation, a padlock can be configured to prevent unauthorized personnel from misoperating.
6. Counter indication
7. Isolating switch operating hole and grounding switch operating hole padlock device
The padlock plate linked to the padlock device blocks the grounding switch operating hole or the isolating operating hole. Only by pulling the padlock device can the operating handle be inserted into the grounding switch operating hole or the isolating switch operating hole. When not in operation, a padlock can be configured to prevent unauthorized personnel from misoperating.
8. Earthing switch operation hole
9. Earthing electromagnetic lock
10. Door handle
11. Cable connection room
The cable connection room is equipped with a bushing that meets the DIN47636 standard, and the incoming and outgoing cables are connected through a fully insulated and fully sealed detachable connector (cable connector)
12. Fault indicator
13. Main switch energy storage indication
14. Main switch closing button
15. Main switch opening button
16. Isolating switch operation hole
17. Fuse tripping indication
18. Observation window lighting button
19. Observation window

Product Features

  • Complex and integrated products
    The inflatable shell of the switchgear is made of high-quality 2.5mm thick stainless steel plate through laser welding, which ensures the airtight reliability of the gas box, high mechanical strength, good corrosion resistance, and the protection level of the inflatable shell reaches IP67: the gas box is equipped with an explosion-proof diaphragm, which can effectively prevent damage to people and equipment caused by excessive air pressure: all conductive parts are enclosed in the gas box, which can not only avoid the influence of external environmental factors, but also improve the operating reliability, making it maintenance-free (or less maintenance) and meeting the requirements of miniaturization.
    The main circuit adopts a combination of a three-position switch (connection + isolation + grounding) and a vacuum interrupter. This structure is the most mature configuration method at present, and is particularly suitable for the current power grid operation and maintenance needs.
  • Environmental and pollution-free
    The insulating medium of the DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear is zero-grade dry air (purchased from outside) or 99.99% pure N2 in accordance with GB/T8979-2008. Gas leakage will not cause any impact on the external environment, and no recycling treatment is required.
  • Perfect mechanical interlocking
    The operation panel of DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear has perfect five-protection mechanical interlocking function, and all interlocking functions are configured internally. Please follow the operation instructions for operation, which is very convenient to use.
  • Flexible expansion design
    DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear is modularly designed. Various modules can be connected through dedicated busbar connectors. A variety of unit combinations are achieved to maximize meet the complex and diverse power distribution design schemes in various parts of China.

Working Environment

  • Altitude: ≤ 2000m (If the installation altitude exceeds 2000m, please contact Dongshengyuan Company).
  • Ambient temperature: Maximum: 40°C, Minimum: -40°C; the average temperature within 24 hours should not exceed 35°C.
  • Humidity: The 24-hour average relative humidity should not exceed 95%, and the monthly average relative humidity should not exceed 90%.
  • Installation environment: The surrounding air should be free from explosive and corrosive gases, and the installation site should not experience severe vibrations or impacts.
  • Seismic resistance: Level 8.

Tecnical Parameter

Shape and related dimensions:

Basic Switchgear Module Introduction

Vacuum Circuit Breaker Unit

 

 

Standard configuration and features:
630A/1250A busbar
vacuum circuit breaker
Electric operating mechanism for vacuum switch
Three-position disconnector
Manual operating mechanism for three-position disconnector
Position indicator for vacuum switch and three-position disconnector
Cable connection bushing
Capacitive voltage indicator showing bushing live
Barometer
Padlocking device
Switchgear body
Wiring busbar
Operating handle
Current transformer (special for protection)
Digital relay protection device

Optional configuration and features:
Short circuit and ground fault indicator
Detachable connector (cable connector)
Lightning arrester
Live/grounded locking device for incoming line
Key mechanical interlocking device
Ring current transformer and meter

Switchgear with Load Switch

Standard configuration and features
630A busbar
Vacuum load switch
Manual operating mechanism of vacuum load switch
Three-position disconnector
Manual operating mechanism of three-position disconnector
Position indicator of three-position disconnector of load switch
Cable wiring bushing
Capacitive voltage indicator showing bushing voltage
Voltage gauge
Padlocking device
Grounding busbar of switchgear
Operating handleOptional configuration and features:
Electric operating mechanism of vacuum load
Separable connector (cable connector)
Lightning arrester
Live/grounding locking device for incoming line
Key mechanism and locking device
Toroidal current transformer

 

 

Standard configuration and features:
630 busbar
Manual operating mechanism for vacuum load switch
Three-position disconnector/fuse head and end grounding switch
Manual operating mechanism for three-position disconnector/fuse head grounding switch
Load switch and grounding switch position indicator
Cable connection pipe
Display sleeve energized capacitive voltage indicator
Barometer
Padlocking device
Switchgear body
Grounding busbar
Operating handle
Fuse barrel

Optional configuration and features:
Vacuum load switch operating mechanism
Short circuit and ground fault indicator
Detachable connector (cable connector)
Key mechanical interlocking device
High voltage current limiting fuse
Ring current transformer and meter

 

 

DSY-CV-12/T630-20 Environmentally friendly gas insulated ring main switchgear


Since the 1950s, the development of medium-voltage switchgear has gone through the stages of open type, box type, metal enclosed type, etc.

隐藏域元素占位

  • 产品描述
    • Commodity name: DSY-CV-12/T630-20 Environmentally friendly gas insulated ring main switchgear

    Since the 1950s, the development of medium-voltage switchgear has gone through the stages of open type, box type, metal enclosed type, etc.

    Overview:

    Since the 1950s, the development of medium-voltage switchgear has gone through the stages of open type, box type, metal enclosed type, etc. There is no problem in meeting the functional use requirements of the equipment, and the products have long been serialized and fully covered. Small size, maintenance-free, highly modular, safe and reliable environmentally friendly gas-insulated ring network switchgear has developed rapidly. It can realize remote monitoring, control and management of the power system distribution network, realize the needs of power grid optimization, power safety, power management, energy saving and consumption reduction: the system can also be widely used in intelligent power distribution fields such as transportation, factories, hospitals, schools, buildings, residential areas and commercial office buildings.

    DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear fully introduces advanced production equipment and manufacturing technology to realize localized production, greatly reduce manufacturing costs, shorten delivery cycles, and is well received by users after its launch.

    1. Secondary control box
    2. Microcomputer integrated protection device
    3. Live indicator
    The live indicator shows whether the bushing is live. The three sockets below the indicator can be used for secondary phase checking.
    4. Energy storage operation hole
    Use the operating handle to rotate the energy storage mechanism shaft. Make the main switch operating mechanism store energy
    5. Energy storage operation hole padlock device
    The padlock plate linked to the padlock device blocks the energy storage operation hole. Only by pulling the padlock device can the operating handle be inserted into the energy storage operation hole. When not in operation, a padlock can be configured to prevent unauthorized personnel from misoperating.
    6. Counter indication
    7. Isolating switch operating hole and grounding switch operating hole padlock device
    The padlock plate linked to the padlock device blocks the grounding switch operating hole or the isolating operating hole. Only by pulling the padlock device can the operating handle be inserted into the grounding switch operating hole or the isolating switch operating hole. When not in operation, a padlock can be configured to prevent unauthorized personnel from misoperating.
    8. Earthing switch operation hole
    9. Earthing electromagnetic lock
    10. Door handle
    11. Cable connection room
    The cable connection room is equipped with a bushing that meets the DIN47636 standard, and the incoming and outgoing cables are connected through a fully insulated and fully sealed detachable connector (cable connector)
    12. Fault indicator
    13. Main switch energy storage indication
    14. Main switch closing button
    15. Main switch opening button
    16. Isolating switch operation hole
    17. Fuse tripping indication
    18. Observation window lighting button
    19. Observation window

    Product Features

    • Complex and integrated products
      The inflatable shell of the switchgear is made of high-quality 2.5mm thick stainless steel plate through laser welding, which ensures the airtight reliability of the gas box, high mechanical strength, good corrosion resistance, and the protection level of the inflatable shell reaches IP67: the gas box is equipped with an explosion-proof diaphragm, which can effectively prevent damage to people and equipment caused by excessive air pressure: all conductive parts are enclosed in the gas box, which can not only avoid the influence of external environmental factors, but also improve the operating reliability, making it maintenance-free (or less maintenance) and meeting the requirements of miniaturization.
      The main circuit adopts a combination of a three-position switch (connection + isolation + grounding) and a vacuum interrupter. This structure is the most mature configuration method at present, and is particularly suitable for the current power grid operation and maintenance needs.
    • Environmental and pollution-free
      The insulating medium of the DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear is zero-grade dry air (purchased from outside) or 99.99% pure N2 in accordance with GB/T8979-2008. Gas leakage will not cause any impact on the external environment, and no recycling treatment is required.
    • Perfect mechanical interlocking
      The operation panel of DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear has perfect five-protection mechanical interlocking function, and all interlocking functions are configured internally. Please follow the operation instructions for operation, which is very convenient to use.
    • Flexible expansion design
      DSY-CV-12/T630-20 environmentally friendly gas-insulated ring network switchgear is modularly designed. Various modules can be connected through dedicated busbar connectors. A variety of unit combinations are achieved to maximize meet the complex and diverse power distribution design schemes in various parts of China.

    Working Environment

    • Altitude: ≤ 2000m (If the installation altitude exceeds 2000m, please contact Dongshengyuan Company).
    • Ambient temperature: Maximum: 40°C, Minimum: -40°C; the average temperature within 24 hours should not exceed 35°C.
    • Humidity: The 24-hour average relative humidity should not exceed 95%, and the monthly average relative humidity should not exceed 90%.
    • Installation environment: The surrounding air should be free from explosive and corrosive gases, and the installation site should not experience severe vibrations or impacts.
    • Seismic resistance: Level 8.

    Tecnical Parameter

    Shape and related dimensions:

    Basic Switchgear Module Introduction

    Vacuum Circuit Breaker Unit

     

     

    Standard configuration and features:
    630A/1250A busbar
    vacuum circuit breaker
    Electric operating mechanism for vacuum switch
    Three-position disconnector
    Manual operating mechanism for three-position disconnector
    Position indicator for vacuum switch and three-position disconnector
    Cable connection bushing
    Capacitive voltage indicator showing bushing live
    Barometer
    Padlocking device
    Switchgear body
    Wiring busbar
    Operating handle
    Current transformer (special for protection)
    Digital relay protection device

    Optional configuration and features:
    Short circuit and ground fault indicator
    Detachable connector (cable connector)
    Lightning arrester
    Live/grounded locking device for incoming line
    Key mechanical interlocking device
    Ring current transformer and meter

    Switchgear with Load Switch

    Standard configuration and features
    630A busbar
    Vacuum load switch
    Manual operating mechanism of vacuum load switch
    Three-position disconnector
    Manual operating mechanism of three-position disconnector
    Position indicator of three-position disconnector of load switch
    Cable wiring bushing
    Capacitive voltage indicator showing bushing voltage
    Voltage gauge
    Padlocking device
    Grounding busbar of switchgear
    Operating handleOptional configuration and features:
    Electric operating mechanism of vacuum load
    Separable connector (cable connector)
    Lightning arrester
    Live/grounding locking device for incoming line
    Key mechanism and locking device
    Toroidal current transformer

     

     

    Standard configuration and features:
    630 busbar
    Manual operating mechanism for vacuum load switch
    Three-position disconnector/fuse head and end grounding switch
    Manual operating mechanism for three-position disconnector/fuse head grounding switch
    Load switch and grounding switch position indicator
    Cable connection pipe
    Display sleeve energized capacitive voltage indicator
    Barometer
    Padlocking device
    Switchgear body
    Grounding busbar
    Operating handle
    Fuse barrel

    Optional configuration and features:
    Vacuum load switch operating mechanism
    Short circuit and ground fault indicator
    Detachable connector (cable connector)
    Key mechanical interlocking device
    High voltage current limiting fuse
    Ring current transformer and meter

     

     