GCS low-voltage withdrawable switchgear
+
  • GCS low-voltage withdrawable switchgear

OVERVIEW:

GCS low-voltage withdrawable switchgear is suitable for power distribution systems in power plants, petroleum, chemical, metallurgy, textile, high-rise buildings and other industries. In large power plants, petrochemical systems and other places with high automation and computer interface requirements.

KEY ADVANTAGES:

  1. Comprehensive Power Distribution: Functions as a complete set of power distribution equipment.
  2. Reactive Power Distribution: Functions as a complete set of power distribution equipment.
  3. Frequency and Voltage Ratings

BASIC PARAMETERS:

Project Parameter
Main circuit rated voltage (V) Communication 380(400), (660)V
Auxiliary circuit rated voltage (V) Communication 220V, 380 (400)V DC 110/220V
Rated frequency (Hz) 50(60)Hz
Rated insulation voltage (V) 660(1000)V
Rated current (A) Horizontal busbar, vertical busbar (MCC) ≤ 4000A、1000A
Busbar rated short-time withstand current (kA/1s) 50kA/s,80kA/s
Busbar rated peak withstand current (kA/0.1s) 105kA/0.1s,176kA/0.1s
Power frequency test voltage (V/1min) Main circuit, auxiliary circuit 2500V/1min、1760V/1min
Busbar Three-phase four-wire system, three-phase five-wire system A,B,C,PEN、A,B,C,PE,N
Protection level IP30,IP40

 

OPERATING CONDITIONS:

  • Operating temperature range: -5°C to +40°C, with a daily maximum of +35°C. Capacity should adjust based on actual conditions if outside the specified range.
  • Indoors, at an altitude up to 2000 meters.
  • Variations in ambient humidity may occasionally result in slight moisture accumulation.
  • The tilt of the device’s installation position should not exceed 5% from vertical.
  • Environments free from flammable, explosive materials, corrosive chemicals, and frequent or intense vibrations.

 

This LV GCS switchgear is integral for ensuring safe and efficient power management in complex industrial environments.

GCS low-voltage withdrawable switchgear


Suitable for power distribution systems in power plants, petroleum, chemical, metallurgy, textile, high-rise buildings and other industries. It’s used as a low-voltage complete set of power distribution equipment for power distribution, motor centralized control, and reactive power compensation in power generation and power supply systems with a three-phase AC frequency of 50 (60) Hz, a rated working voltage of 380V (400V), (660V), and a rated current of 4000A or less.

隐藏域元素占位

  • 产品描述
    • Commodity name: GCS low-voltage withdrawable switchgear

    Suitable for power distribution systems in power plants, petroleum, chemical, metallurgy, textile, high-rise buildings and other industries. It’s used as a low-voltage complete set of power distribution equipment for power distribution, motor centralized control, and reactive power compensation in power generation and power supply systems with a three-phase AC frequency of 50 (60) Hz, a rated working voltage of 380V (400V), (660V), and a rated current of 4000A or less.

    OVERVIEW:

    GCS low-voltage withdrawable switchgear is suitable for power distribution systems in power plants, petroleum, chemical, metallurgy, textile, high-rise buildings and other industries. In large power plants, petrochemical systems and other places with high automation and computer interface requirements.

    KEY ADVANTAGES:

    1. Comprehensive Power Distribution: Functions as a complete set of power distribution equipment.
    2. Reactive Power Distribution: Functions as a complete set of power distribution equipment.
    3. Frequency and Voltage Ratings

    BASIC PARAMETERS:

    Project Parameter
    Main circuit rated voltage (V) Communication 380(400), (660)V
    Auxiliary circuit rated voltage (V) Communication 220V, 380 (400)V DC 110/220V
    Rated frequency (Hz) 50(60)Hz
    Rated insulation voltage (V) 660(1000)V
    Rated current (A) Horizontal busbar, vertical busbar (MCC) ≤ 4000A、1000A
    Busbar rated short-time withstand current (kA/1s) 50kA/s,80kA/s
    Busbar rated peak withstand current (kA/0.1s) 105kA/0.1s,176kA/0.1s
    Power frequency test voltage (V/1min) Main circuit, auxiliary circuit 2500V/1min、1760V/1min
    Busbar Three-phase four-wire system, three-phase five-wire system A,B,C,PEN、A,B,C,PE,N
    Protection level IP30,IP40

     

    OPERATING CONDITIONS:

    • Operating temperature range: -5°C to +40°C, with a daily maximum of +35°C. Capacity should adjust based on actual conditions if outside the specified range.
    • Indoors, at an altitude up to 2000 meters.
    • Variations in ambient humidity may occasionally result in slight moisture accumulation.
    • The tilt of the device’s installation position should not exceed 5% from vertical.
    • Environments free from flammable, explosive materials, corrosive chemicals, and frequent or intense vibrations.

     

    This LV GCS switchgear is integral for ensuring safe and efficient power management in complex industrial environments.

Get A Quote