DSY-12/24 SF6 Gas Insulated Permanent Magnet Circuit Breaker Switchgear
+
  • DSY-12/24 SF6 Gas Insulated Permanent Magnet Circuit Breaker Switchgear

Overview:

It features SF6 gas insulation, a permanent magnet operating mechanism, and a vacuum circuit breaker. It is particularly well-suited for applications requiring frequent operations under rated current or multiple interruptions of short-circuit currents. The circuit breaker performs opening and closing operations through coordination between the controller and the permanent magnet operating mechanism. Each phase operates independently, with a simple and reliable transmission mechanism, ensuring short inherent opening and closing times (opening time ≤ 7ms, closing time ≤ 30ms), enabling quick clearing of downstream faults. The mechanical lifespan exceeds 20,000 operations and it includes a manual quick trip function. The permanent magnet circuit breaker is characterized by its fast tripping response (fault clearing time less than 15ms) and high mechanical stability. The product’s technical performance meets the specifications for permanent magnet circuit breakers set by both Southern Power Grid and State Grid.

The secondary circuit adopts integrated control technology and supports data transmission functions. When the equipment is installed and powered on in the field, it automatically sends a signal to the main station for the first handshake. The main station will obtain the equipment’s health status, geographical coordinates, operating environment, and operating parameters, facilitating timely monitoring of the equipment’s operational status by maintenance personnel.

Main Parameters:

Rated frequency/voltage/current:  50Hz/12kV/630A
Rated power frequency withstand voltage:  42/48kV
Rated power frequency withstand voltage:  75/85kV
Rated short-circuit breaking current:  20, 25kA
Rated short-time withstand current: 20, 25kA/4s
Permanent magnet circuit breaker tripping time:  ≤ 15ms
Loss of service continuity category:  LSC2A
Internal arc classification:  IAC A FL 20, 25kA/1S
Switch/switchgear enclosure protection rating:  IP67/IP41

Operating environment:

  •  Ambient temperature: -40°C to 60°C (customization required for temperatures below -25°C).
  •  Relative humidity: ≤ 95%.
  •  Altitude: ≤ 2000 meters.
  •  Earthquake resistance: Grade 8.
  •  Particularly suitable for applications in high-altitude, coastal, extremely cold, and heavily polluted areas.

Features:

  1.  The structure design of the three-phase independent monostable permanent magnet mechanism equips each vacuum interrupter with an operating mechanism; it utilizes a fully linear motion to achieve the highest transmission efficiency.
  2.  With a simple structure comprising fewer than 50 parts, the direct-drive design effectively overcomes mechanical failures, greatly improving reliability compared to spring mechanisms, and the mechanism has a lifespan of over 50,000 operations.
  3.  The mechanism employs electromagnetic closing, permanent magnetic holding, and spring tripping, with maximum rigid closing and tripping speeds. The current interruption time is less than 15ms.
  4.  It is equipped with a specially designed fast manual tripping mechanism to ensure consistency between manual and electric operation characteristics.
  5.  A three-phase synchronization shaft is installed to maintain the consistency of phase recovery, and the synchronization shaft indicates the breaker’s open/close position.
  6.  All high-voltage live circuits are housed within a stainless steel gas chamber, ensuring operation is unaffected by external environmental conditions.

DSY-12/24 SF6 Gas Insulated Permanent Magnet Circuit Breaker Switchgear


This product is suitable for use in three-phase AC power systems with a rated voltage of 12kV and frequency of 50Hz

隐藏域元素占位

  • 产品描述
    • Commodity name: DSY-12/24 SF6 Gas Insulated Permanent Magnet Circuit Breaker Switchgear

    This product is suitable for use in three-phase AC power systems with a rated voltage of 12kV and frequency of 50Hz

    Overview:

    It features SF6 gas insulation, a permanent magnet operating mechanism, and a vacuum circuit breaker. It is particularly well-suited for applications requiring frequent operations under rated current or multiple interruptions of short-circuit currents. The circuit breaker performs opening and closing operations through coordination between the controller and the permanent magnet operating mechanism. Each phase operates independently, with a simple and reliable transmission mechanism, ensuring short inherent opening and closing times (opening time ≤ 7ms, closing time ≤ 30ms), enabling quick clearing of downstream faults. The mechanical lifespan exceeds 20,000 operations and it includes a manual quick trip function. The permanent magnet circuit breaker is characterized by its fast tripping response (fault clearing time less than 15ms) and high mechanical stability. The product’s technical performance meets the specifications for permanent magnet circuit breakers set by both Southern Power Grid and State Grid.

    The secondary circuit adopts integrated control technology and supports data transmission functions. When the equipment is installed and powered on in the field, it automatically sends a signal to the main station for the first handshake. The main station will obtain the equipment’s health status, geographical coordinates, operating environment, and operating parameters, facilitating timely monitoring of the equipment’s operational status by maintenance personnel.

    Main Parameters:

    Rated frequency/voltage/current:  50Hz/12kV/630A
    Rated power frequency withstand voltage:  42/48kV
    Rated power frequency withstand voltage:  75/85kV
    Rated short-circuit breaking current:  20, 25kA
    Rated short-time withstand current: 20, 25kA/4s
    Permanent magnet circuit breaker tripping time:  ≤ 15ms
    Loss of service continuity category:  LSC2A
    Internal arc classification:  IAC A FL 20, 25kA/1S
    Switch/switchgear enclosure protection rating:  IP67/IP41

    Operating environment:

    •  Ambient temperature: -40°C to 60°C (customization required for temperatures below -25°C).
    •  Relative humidity: ≤ 95%.
    •  Altitude: ≤ 2000 meters.
    •  Earthquake resistance: Grade 8.
    •  Particularly suitable for applications in high-altitude, coastal, extremely cold, and heavily polluted areas.

    Features:

    1.  The structure design of the three-phase independent monostable permanent magnet mechanism equips each vacuum interrupter with an operating mechanism; it utilizes a fully linear motion to achieve the highest transmission efficiency.
    2.  With a simple structure comprising fewer than 50 parts, the direct-drive design effectively overcomes mechanical failures, greatly improving reliability compared to spring mechanisms, and the mechanism has a lifespan of over 50,000 operations.
    3.  The mechanism employs electromagnetic closing, permanent magnetic holding, and spring tripping, with maximum rigid closing and tripping speeds. The current interruption time is less than 15ms.
    4.  It is equipped with a specially designed fast manual tripping mechanism to ensure consistency between manual and electric operation characteristics.
    5.  A three-phase synchronization shaft is installed to maintain the consistency of phase recovery, and the synchronization shaft indicates the breaker’s open/close position.
    6.  All high-voltage live circuits are housed within a stainless steel gas chamber, ensuring operation is unaffected by external environmental conditions.

Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit