SF6 Load Break Switch FLN36-7.2-24kV
+
  • SF6 Load Break Switch FLN36-7.2-24kV

Overview:

The FLN36 SF6 gas-insulated load break switch is a dual-break rotary switch that utilizes sulfur hexafluoride gas as the insulating and arc-extinguishing medium, designed for 7.2-24kV XGN15-12 RMU distribution systems. Each load break switch is filled with SF6 gas at a pressure of 0.4 bar, with the gas permanently sealed inside.

Advantages:

  • Safety: Manufactured to the highest IEC standards, featuring a non-corrosive, leak-proof enclosure, inspection windows, built-in voltage indicator, interlocking mechanism, gas pressure gauge, and more.
  • Cost-efficiency: A lifespan of at least 30 years, maintenance-free due to its sealed-for-life design, and low operating costs.
  • Reliability: Each unit undergoes rigorous testing, equipped with a highly durable and reliable actuator, proven in global applications.
  • Intelligent integration: Modular design, compact form, easy to install, and versatile, suitable for a wide range of applications with a single switch.

Baisc Parameter:

Switch Type   FLN36 Switch
Rated voltage Ur [kv] 7.2/12/24
Rated insulation voltage Us [kV] 7.2112124
Withstand voltage Ud(1min)[kV] 30/42/65(common value)34/48/79 (across the isolating distance)
Impulse withstand voltage Up [kV] 60/75/125(common value)70/85/145(across the isolating distance)
Raged frequency Fr [HZ] 50/60
Rated current Ir [A] 630
Rated short-time withstand current (3s) [KA] 25
Rated peak withstand current [KA] 63
Rated short-time current duration [s] 3
Auxiliary circuit power frequency withstand
voltage (1min)
[V] 2000
Rated active load breaking current [A] 630
Rated closed circuit breaking current [A] 630
No-load transformer capacity [KAV] 1250
Cable charging current [A] 10
SF6 gas rated inflation pressure
20 “Cgauge pressure)
[MPA] 0.045+0.005
SF6 gas yearly leakage rate [per year] ≤10%
Vechanical endurance (earthing) [cycles] 2,000
Different period of three-phase closing [ms] ≤5
Mechanical endurance(switch) [cycles] 5,000

Keywords

SF6 Load Break Switch FLN36-7.2-24kV


The FLN36 SF6 gas-insulated load break switch is a dual-break rotary switch that utilizes sulfur hexafluoride gas as the insulating and arc-extinguishing medium, designed for 7.2-24kV XGN15-12 RMU distribution systems. Each load break switch is filled with SF6 gas at a pressure of 0.4 bar, with the gas permanently sealed inside.

隐藏域元素占位

  • 产品描述
    • Commodity name: SF6 Load Break Switch FLN36-7.2-24kV

    The FLN36 SF6 gas-insulated load break switch is a dual-break rotary switch that utilizes sulfur hexafluoride gas as the insulating and arc-extinguishing medium, designed for 7.2-24kV XGN15-12 RMU distribution systems. Each load break switch is filled with SF6 gas at a pressure of 0.4 bar, with the gas permanently sealed inside.

    Overview:

    The FLN36 SF6 gas-insulated load break switch is a dual-break rotary switch that utilizes sulfur hexafluoride gas as the insulating and arc-extinguishing medium, designed for 7.2-24kV XGN15-12 RMU distribution systems. Each load break switch is filled with SF6 gas at a pressure of 0.4 bar, with the gas permanently sealed inside.

    Advantages:

    • Safety: Manufactured to the highest IEC standards, featuring a non-corrosive, leak-proof enclosure, inspection windows, built-in voltage indicator, interlocking mechanism, gas pressure gauge, and more.
    • Cost-efficiency: A lifespan of at least 30 years, maintenance-free due to its sealed-for-life design, and low operating costs.
    • Reliability: Each unit undergoes rigorous testing, equipped with a highly durable and reliable actuator, proven in global applications.
    • Intelligent integration: Modular design, compact form, easy to install, and versatile, suitable for a wide range of applications with a single switch.

    Baisc Parameter:

    Switch Type   FLN36 Switch
    Rated voltage Ur [kv] 7.2/12/24
    Rated insulation voltage Us [kV] 7.2112124
    Withstand voltage Ud(1min)[kV] 30/42/65(common value)34/48/79 (across the isolating distance)
    Impulse withstand voltage Up [kV] 60/75/125(common value)70/85/145(across the isolating distance)
    Raged frequency Fr [HZ] 50/60
    Rated current Ir [A] 630
    Rated short-time withstand current (3s) [KA] 25
    Rated peak withstand current [KA] 63
    Rated short-time current duration [s] 3
    Auxiliary circuit power frequency withstand
    voltage (1min)
    [V] 2000
    Rated active load breaking current [A] 630
    Rated closed circuit breaking current [A] 630
    No-load transformer capacity [KAV] 1250
    Cable charging current [A] 10
    SF6 gas rated inflation pressure
    20 “Cgauge pressure)
    [MPA] 0.045+0.005
    SF6 gas yearly leakage rate [per year] ≤10%
    Vechanical endurance (earthing) [cycles] 2,000
    Different period of three-phase closing [ms] ≤5
    Mechanical endurance(switch) [cycles] 5,000

Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit